Server: kootenai idl> .r msu_xrtdv frequently used words when it is normal: [1] Check HouseKeeping and Health & Safety. All HK readings are in the expected ranges. C_C0_STAT keyword remains normal at 0. ## eclipse season: The temperatures decrease due to the eclipse season. The temperatures continue to decrease due to the eclipse season. [noticable but not important] TMP10C (Sun Shield) decreases possibly due to the coming Hinode's night(eclipse) from 5/8 05:25UT. ##bakeout The temperatures rise after the start of the CCD bakeout at around 5/5 14:35UT. The temperatures began to decease after CCD heater off on 5/8 14:35UT. ##recal A small spike in TMP21C at ~18UT on 5/8 corresponds to the expected Focus recal. [2] Review XRT data ## flare mode data, check the return of msu_xrtdv No flare mode data in report period. ##pointing The synoptic images are shifted towards west and thus the west limb is outside of FOV, possibly due to the effects noted by Shimizu-San on 5/7 in xrt_co:34877 email. ##saturation [no need to report for synoptic images or CME watch] Saturated pixels (~100) in Al-mesh, Al-poly, Thin_Be low exposure images. notes: note 1. need to make sure if flaring activity causing the saturation note 2. be careful with the flare mode images, if/not continuously saturated...stray light leak note 3. G-Band Alignment with N/S Pole, saturation in G-band is expected. Note: [1] bug for msu_xrtdv: when the last image for a timeline is synoptic image, it can continues to show "No times between t0 and t1, returning record closest to t0" to avoid this, make the end time slightly before the final data of that timeline (check the available quick look data first).