AEC and PFB

(3-Aug-2019, initial version by Aki Takeda)

Close look at XOB #1BCB (for HOP362: coordination with Hida and IRIS)

AEC: Automatic Exposure Control

AEC in the Blue Book

Current setting of AEC table (#000A).

AEC No. ULT LLT UFR LFR UFR/(2^16) LFR/(2^16)
1 2500 500 16 500 0.02% 0.76%
2 2500 2500 3932 665 6.0% 1.0%
3 2500 500 0 500 0% 0.76%

PFB: Pre Flare Buffer

PFB in the Blue Book (1)
PFB in the Blue Book (2)