TIME OF FIRST ENTRANCE FILTER FAILURE I have re-examined the FFI data around the time of the first big SXT entrance filter failure. These data are from a small area in the lower right corner of DPE=25 AlMg images. The data were decompressed but not otherwise processed. The FFI data indicate that the entrance filter failed between the time of the last FFI in sfr921113.1637 and the first FFI in sfr921113.1814. Although only the AlMg data are shown here this conclusion is consistent with all of the FFI images. Presently the time of the first entrance filter failure in get_yo_dates is 13-Nov-92 16:50:00. I do not recall where that time came from. This analysis indicates that a more accurate time of the first entrance filter failure is 13-Nov-92 18:00:00. Recall that this is not the time of the zeroeth entrance filter failure which took place shortly before 27-Oct-92 16:26. That failure caused only a small increase of straylight in the aspect images. L. Acton 1/27/98