Documentation > SXT Observation Notes > this page |
Image name: att_91_97.png (click image to enlarge)
Image size: 20.4930 KB (1024x512)
Date submitted: 13-Jan-1998
Drift of ATT Pointing The figure shows the drift of the ATT pointing solution relative to the SXT. The ATT pointing solution is derived from HXA data and the SXT pointing from the X-ray limb in SXT images. The solid (green) line shows a fit to the slowly varying component. The discrepancy in the N-S direction has recently grown to nearly 4 arcseconds which has a significant impact on coordinated data analysis. I plan to update the ATT pointing solution in the near future. I propose to subtract the slowly varying component in the N-S direction (green line in bottom panel). The E-W discrepancy is too small to warrant action at this time. JPW 13-Jan-98